Pressure Regulator Vulkan F 15/300 2F Effect with 2 Flow Meters

The Vulkan F 15/300 2F Effect with 2 Flow Meters is a single-stage cylinder pressure regulator acc. to ISO 2503 with integrated high-pressure compensation and two independent flowmeters, enabling simultaneous precise flow control for two separate working processes from one cylinder. Designed for dual-station welding and forming gas applications from 200 or 300 bar cylinders.

SKU: VUL-FDR-8 Category:

Description

The F 15/300 2F Effect supplies two simultaneous working processes from a single cylinder, each with its own independent flowmeter and flow setting in Nl/min. This eliminates the need for two separate regulators at dual-station welding or forming gas installations.

The Vulkan Effect maintains constant working pressure as the cylinder depletes, keeping both flowmeter readings accurate throughout the working cycle.

The F-series is available with factory-fitted inlet connections for any national or international cylinder valve standard — covering Europe (DIN 477, AFNOR, UNI, NEN, SMS), North and South America (CGA, ABNT, IRAM), UK and Commonwealth (BS 341, AS 2473) and specialty standards (ISO 5145, NPT, BSPP). Every connection is pressure-tested at the factory. This eliminates the need for third-party adapters and ensures the complete assembled unit complies with ISO 2503 from cylinder valve to outlet. A full reference table of available connections and article numbers is provided in Table 3.

 

Key Advantages

  • Two independent flowmeters for simultaneous flow control of two processes from one cylinder.
  • Eliminates need for two separate regulators at dual-station installations.
  • Vulkan Effect keeps both flow settings accurate as the cylinder depletes.
  • Available for 200 bar and 300 bar inlet cylinders.
  • Factory-fitted international connections — no adapters required.

 

Food-Gas / Compliance Positioning

This regulator can be positioned for food-gas projects when ordered with the appropriate wetted materials, elastomers, cleanliness level and documentation package. Regulation (EC) No 1935/2004 defines the basic requirement that materials in contact with food must not transfer substances in quantities that could endanger health or unacceptably change the composition or organoleptic properties of food. Regulation (EC) No 2023/2006 adds GMP requirements for controlled manufacturing processes. In Germany, LFGB is part of the legal framework used for control of food-contact materials and articles.

 

Table 1. Technical Data

Parameter Value
Body Brass
Seals Polyamide, EPDM
Diaphragm EPDM
Leakage rate 1 × 10⁻⁶ mbar l/s
Temperature -20 to +60 °C
Max. inlet pressure 200 / 300 bar
Outlets 2 × independent flowmeter outlets
Width (B) 250 mm
Height (H) 230 mm
Depth (T) 130 mm
Weight (M) 2.0 kg

 

Table 2. Versions and Article Numbers

Gas type Inlet / Flow range Pressure Inlet Outlet (2×) Art. no.
CO₂/Argon 200 bar  0.5–5.0 Nl/min. 4.5 bar W21.8×1/14RH nut G 1/4 RH×6 mm 226 711 11
CO₂/Argon 200 bar  1.0–15.0 Nl/min. 2.5 bar 226 700 11
CO₂/Argon 200 bar  3.0–30.0 Nl/min. 2.5 bar 226 702 11
Nitrogen 200 bar  5.0–50.0 Nl/min. 4.5 bar W24.32×1/14RH nut 223 712 11
Hydrogen 200 bar  3.0–34.0 Nl/min. 4.5 bar W21.8×1/14LH nut G 3/8 LH×9 mm 224 706 11
Forming gas 200 bar  3.0–34.0 Nl/min. 2.5 bar 224 710 11
CO₂/Argon 300 bar  0.5–5.0 Nl/min. 4.5 bar W 30×2RH nut G 1/4 RH×6 mm 326 711 11
CO₂/Argon 300 bar  1.0–15.0 Nl/min. 2.5 bar 326 700 11
CO₂/Argon 300 bar  3.0–30.0 Nl/min. 2.5 bar 326 702 11
Nitrogen 300 bar  5.0–50.0 Nl/min. 4.5 bar 323 712 11
Hydrogen 300 bar  3.0–34.0 Nl/min. 4.5 bar W 30×2LH nut G 3/8 LH×9 mm 324 706 11
Forming gas 300 bar  3.0–34.0 Nl/min. 2.5 bar 324 710 11

 

Table 3. International Cylinder Connections

Every Vulkan F-series regulator can be supplied with factory-fitted inlet connections matching any national or international cylinder valve standard. Factory fitting eliminates the need for third-party adapters — every connection is pressure-tested at the factory, ensuring leak-proof performance and full compliance with ISO 2503 for the complete assembled unit. Connection-specific materials and seals are selected according to the gas type and standard requirements. The result is a regulator ready for immediate integration with the local cylinder fleet — without additional site adaptation.

 

CO₂ / Argon — international cylinder connections:

Region / Country Standard VDMA no. Connection type Article no.
Australia AS2473, Type 30 4.1 nut 0.860×1/14 RHf 912 401
Germany, Belgium, Finland, Austria, Poland, CH DIN 477-1, No. 6 4.2 nut W21.8×1/14 RHf 912 402
France, Spain, Portugal, Greece, N. Africa (also Ar, N₂) NFE29650 Type C 4.3 nut W21.7×1/14 RHk/f 912 403
UK, Egypt, Asia, S. Africa, Arabia BS341-3, No. 8 4.4 nut 0.860×1/14 RHf 912 404
Belgium, Netherlands NEN RU1 4.5 nut W21.8×1/14 RHf 912 405
USA, South America CGA 320 4.6 nut 0.830×1/14 RHf 912 406
Switzerland SN 219 505 Bl.7 4.7 nut W21.8×1/14 RHf 912 407

 

Nitrogen — international cylinder connections:

Region / Country Standard VDMA no. Connection type Article no.
Denmark, Norway DS727.3 5.1 nut W24.32×1/14 RHf 912 501
Netherlands, Sweden NEN RU3 5.3 nut W24.32×1/14 RHf 912 503
Sweden SS2238, Type A 5.4 nut W24.32×1/14 RHf 912 504
USA, South America CGA 580 5.5 AG 0.960×1/14 RHk 912 505
Germany, Finland, Austria, Poland, CH, SK, CZ DIN 477-1, No. 10 7.1 nut W24.32×1/14 RHf 912 701
Italy UNI 4409 7.2 AG W21.7×1/14 RHf 912 702

 

Hydrogen — international cylinder connections:

Region / Country Standard VDMA no. Connection type Article no.
Germany, Finland, Norway, Austria, Poland, Sweden, CH, SK, CZ DIN 477-1, No. 1 3.1 nut W21.8×1/14 LHf 912 301
France, Spain, Portugal, Greece, N. Africa NFE29650 Type E 3.2 nut W21.7×1/14 LHk 912 302
UK, Egypt, Asia, S. Africa, Arabia BS341-3, No. 4 3.3 AG G5/8A-LHk 912 303
Italy UNI 4405 3.5 nut W20×1/14 LHf 912 305
Netherlands NEN LU1 3.6 nut W21.8×1/14 LHf 912 306
Denmark DS727.1 6.1 nut W21.8×1/14 LHf 912 601
USA, South America CGA 350 6.4 nut 0.830×1/14 RHk 912 604