Pressure Regulator Vulkan F 10/300 Effect

The Vulkan F 10/300 Effect is a single-stage cylinder pressure regulator acc. to ISO 2503 with integrated high-pressure compensation, delivering stable 0–10 bar outlet pressure from 200 or 300 bar cylinders. Adiabatic compression tested for oxygen and acetylene. Covers the widest gas range in the series including oxygen, acetylene, CO₂, argon, helium, nitrogen, hydrogen, forming gas, compressed air, testing gas, nitrous oxide and methane.

SKU: VUL-FDR-1 Category:

Description

The Vulkan F 10/300 Effect is a single-stage cylinder pressure regulator according to ISO 2503. The integrated Vulkan Effect high-pressure compensation system keeps the outlet pressure constant as the cylinder depletes. Without this compensation, working pressure rises as the cylinder pressure drops, increasing gas consumption by more than 50% with 300 bar cylinders. The Effect eliminates this drift, delivering stable process conditions and measurable gas savings throughout the cylinder working cycle.

The Vulkan Effect is an integrated high-pressure compensation system. Without it, outlet pressure rises as cylinder pressure drops, increasing gas consumption by more than 50% with 300 bar cylinders. With the Effect, outlet pressure remains constant throughout the working cycle, delivering stable process conditions and measurable gas savings.

The brass body with polyamide and EPDM seals, EPDM diaphragm and 1 × 10⁻⁶ mbar l/s leakage rate are the documented standard construction. Gas-specific inlet connections cover the full range from oxygen and acetylene through CO₂/argon, helium, nitrogen, hydrogen and forming gas to compressed air, testing gas, nitrous oxide and methane. Adiabatic compression tested for oxygen and acetylene service.

The F-series is available with factory-fitted inlet connections for any national or international cylinder valve standard — covering Europe (DIN 477, AFNOR, UNI, NEN, SMS), North and South America (CGA, ABNT, IRAM), UK and Commonwealth (BS 341, AS 2473) and specialty standards (ISO 5145, NPT, BSPP). Every connection is pressure-tested at the factory. This eliminates the need for third-party adapters and ensures the complete assembled unit complies with ISO 2503 from cylinder valve to outlet. A full reference table of available connections and article numbers is provided in Table 3.

 

Key Advantages

  • Vulkan Effect: constant outlet pressure throughout the cylinder working cycle — measurable gas savings versus uncompensated regulators.
  • Single-stage acc. to ISO 2503; adiabatic compression tested for oxygen and acetylene.
  • Widest gas range: oxygen, acetylene, CO₂/argon, helium, nitrogen, hydrogen, forming gas, compressed air, testing gas, nitrous oxide, methane.
  • Available for 200 bar and 300 bar inlet cylinders.
  • Factory-fitted international connections for any cylinder valve standard — no adapters required.
  • Brass body, EPDM diaphragm, leakage rate 1 × 10⁻⁶ mbar l/s.

 

Food-Gas / Compliance Positioning

This regulator can be positioned for food-gas projects when ordered with the appropriate wetted materials, elastomers, cleanliness level and documentation package. Regulation (EC) No 1935/2004 defines the basic requirement that materials in contact with food must not transfer substances in quantities that could endanger health or unacceptably change the composition or organoleptic properties of food. Regulation (EC) No 2023/2006 adds GMP requirements for controlled manufacturing processes. In Germany, LFGB is part of the legal framework used for control of food-contact materials and articles.

 

Table 1. Technical Data

Parameter Value
Body Brass
Seals Polyamide, EPDM
Diaphragm EPDM
Leakage rate 1 × 10⁻⁶ mbar l/s
Temperature -20 to +60 °C
Max. inlet pressure 200 / 300 bar
Outlet pressure 0 – 10 bar
Max. flow 46 Nm³/h at 10 bar
Width (B) 210 mm
Height (H) 190 mm
Depth (T) 75 mm
Weight (M) 1.5 kg

 

Table 2. Versions and Article Numbers

Gas type Inlet pressure Pressure Flow Inlet Outlet Art. no.
Oxygen 200 bar 0–10 bar 46 Nm³/h G3/4RH nut G 1/4 RH×6 mm 208 100
Acetylene 20 bar 0–1.5 bar 3.5 Nm³/h clamp G 3/8 LH×9 mm 209 000
CO₂/Argon 200 bar 0–10 bar 46 Nm³/h W21.8×1/14RH nut G 1/4 RH×6 mm 226 005
Helium 226 025
Nitrogen W24.32×1/14RH nut 203 005
Hydrogen W21.8×1/14LH nut G 3/8 LH×9 mm 204 005
Forming gas 204 805
Compressed air G 5/8 RH G 1/4 RH×6 mm 207 005
Testing gas M19×1.5LH nut G 3/8 LH×9 mm 203 805
Nitrous oxide 80 bar G 3/8 RH nut G 1/4 RH×6 mm 203 061
Methane 200 bar W21.8×1/14LH nut G 3/8 LH×9 mm 205 676
Oxygen 300 bar 0–10 bar 46 Nm³/h W 30×2RH nut G 1/4 RH×6 mm 308 100
CO₂/Argon 326 005
Helium 326 025
Nitrogen 303 005
Hydrogen W 30×2LH nut G 3/8 LH×9 mm 304 005
Forming gas 304 805
Compressed air W 30×2RH nut G 1/4 RH×6 mm 307 005
Testing gas W 30×2LH nut G 3/8 LH×9 mm 303 805

 

Table 3. International Cylinder Connections

Every Vulkan F-series regulator can be supplied with factory-fitted inlet connections matching any national or international cylinder valve standard. Factory fitting eliminates the need for third-party adapters — every connection is pressure-tested at the factory, ensuring leak-proof performance and full compliance with ISO 2503 for the complete assembled unit. Connection-specific materials and seals are selected according to the gas type and standard requirements. The result is a regulator ready for immediate integration with the local cylinder fleet — without additional site adaptation.

 

Oxygen — international cylinder connections:

Region / Country Standard VDMA no. Connection type Article no.
Australia (also Ar, N₂) AS 2473, Type 10 1.1 AG G5/8 RHk 912 101
Belgium NBN 226 1.2 AG G5/8 RHk 912 102
Denmark, Norway, Croatia, CZ, SK, SI DS727.2 1.3 nut W21.8×1/14 RHf 912 103
Germany, Austria, Poland, Switzerland, CZ DIN 477-1, No. 9 1.4 nut G3/4 RHf 912 104
France, Spain, Portugal, Greece, N. Africa NFE 29656 1.5 AG W22.91×1/14 RHk 912 105
UK, Egypt, Asia, S. Africa, Arabia (also Ar, N₂) BS 341-3, No. 3 1.6 AG G5/8 RHk 912 106
Italy, Cyprus UNI 4406 1.7 nut W21.7×1/14 RHf 912 107
Netherlands NEN 3268 RI2 1.8 AG G5/8 RHk 912 108
Sweden, Norway, Finland, Greece, Turkey SMS 690 1.9 nut W21.8×1/14 RHf 912 109
Switzerland SN 219 505 Bl.2 1.11 nut G3/4 RHf 912 111
USA, South America CGA 540 1.10 nut 0.908×1/14 RHk 912 110

 

Acetylene — international cylinder connections:

Region / Country Standard VDMA no. Connection type Article no.
Australia (also H₂) AS 2473, Type 20 2.1 AG G5/8 LHk 912 207
Belgium NBN 226, Type D 2.2 clamp 912 202
Denmark, Sweden, Norway, Finland, S. America DS727.7 2.3 AG G3/4 RHf 912 203
Germany, Greece, Austria, Poland, CZ, CH, SK, TR, CY DIN 477-1, No. 3 2.4 clamp 912 204
France, Spain, Portugal, N. Africa NFA 84421, Type 2 2.5 clamp 912 205
France, Spain, Portugal, N. Africa NFE 29658 2.6 AG G5/8 LHk 912 206
UK, Egypt, Asia, S. Africa, Arabia BS 341-3, No. 2 2.7 AG G5/8A-LHk 912 207
Italy UNI 4411 2.8 clamp 912 208
Netherlands NEN 3268 Type 4 2.11 clamp 912 211
USA, Asia CGA 510 2.14 AG 0.880×1/14 LHk 912 214
Switzerland SN 219 505 Bl.6 2.15 AG G3/4 RHf 912 215

 

CO₂ / Argon — international cylinder connections:

Region / Country Standard VDMA no. Connection type Article no.
Australia AS2473, Type 30 4.1 nut 0.860×1/14 RHf 912 401
Germany, Belgium, Finland, Austria, Poland, CH DIN 477-1, No. 6 4.2 nut W21.8×1/14 RHf 912 402
France, Spain, Portugal, Greece, N. Africa (also Ar, N₂) NFE29650 Type C 4.3 nut W21.7×1/14 RHk/f 912 403
UK, Egypt, Asia, S. Africa, Arabia BS341-3, No. 8 4.4 nut 0.860×1/14 RHf 912 404
Belgium, Netherlands NEN RU1 4.5 nut W21.8×1/14 RHf 912 405
USA, South America CGA 320 4.6 nut 0.830×1/14 RHf 912 406
Switzerland SN 219 505 Bl.7 4.7 nut W21.8×1/14 RHf 912 407

 

Nitrogen — international cylinder connections:

Region / Country Standard VDMA no. Connection type Article no.
Denmark, Norway DS727.3 5.1 nut W24.32×1/14 RHf 912 501
Netherlands, Sweden NEN RU3 5.3 nut W24.32×1/14 RHf 912 503
Sweden SS2238, Type A 5.4 nut W24.32×1/14 RHf 912 504
USA, South America CGA 580 5.5 AG 0.960×1/14 RHk 912 505
Germany, Finland, Austria, Poland, CH, SK, CZ DIN 477-1, No. 10 7.1 nut W24.32×1/14 RHf 912 701
Italy UNI 4409 7.2 AG W21.7×1/14 RHf 912 702

 

Hydrogen — international cylinder connections:

Region / Country Standard VDMA no. Connection type Article no.
Germany, Finland, Norway, Austria, Poland, Sweden, CH, SK, CZ DIN 477-1, No. 1 3.1 nut W21.8×1/14 LHf 912 301
France, Spain, Portugal, Greece, N. Africa NFE29650 Type E 3.2 nut W21.7×1/14 LHk 912 302
UK, Egypt, Asia, S. Africa, Arabia BS341-3, No. 4 3.3 AG G5/8A-LHk 912 303
Italy UNI 4405 3.5 nut W20×1/14 LHf 912 305
Netherlands NEN LU1 3.6 nut W21.8×1/14 LHf 912 306
Denmark DS727.1 6.1 nut W21.8×1/14 LHf 912 601
USA, South America CGA 350 6.4 nut 0.830×1/14 RHk 912 604